24 hours Fetal Monitor,fetal heart detector LC602

Model No.︰

LC-602

Brand Name︰

Landcare

Country of Origin︰

China

Unit Price︰

CNY ¥ 5000 / pc

Minimum Order︰

1 pc

Share on:

Product Description

Instructions
LC-602 Fetal Monitor can acquire fetal heart rate, maternal uterine contraction when pregnancies over 28 weeks to provide reference data for clinical use.The monitor can be used individually or connected with PC through RJ45 Interface for the purpose of central monitoring.
It is only suitable for the equipment in hospitals, clinics, doctors offices and patients at home by professional medical personnel.
Major Features
Light dexterous appearance, tops horizontally and walls can be hoisted
8.0 "screen color LCD display, rotatable screen to 60°
Display of the patient data and curve clearly
FHR 120 BPM~160 BPM normal range label
Manual records fetal movement
Sound and color alarm for high and low fetal heart rate
Continuous 24-hour real-time monitoring function
Continuous 12-hour patient curve and data storage , playback and print
With picture freeze function
Optional English interface
Single, Twins Monitoring optional
9 crystal board band pulsed wave transducer
Extra-long life, high-resolution built-in thermal recorder
Built-in communication port, can be connected with central monitoring system.
Main performance

Working Voltage: AC 100 V~240 V Frequency: 50 Hz/60Hz P<60 VA Fuse: T1.6AL250VDisplay
Dimensions: 8.0 "color LCD display, folding 60 degree
Display
Content: bed No. , pregnancy weeks, age, paper speed, date, time , volume, alarm status, transducer connection status, recorder status, FHR data and wave, Contraction data and wave, Fetal move times and mark etc.
Print:
Record Paper two-double type Z
Print Width: 112 mm
Valid Print Width: 104 mm
Paper output speed: 1 cm/min、2 cm/min、3 cm/min(optional)
Data Precision: ±5 %(X Roll),±1 %(Y Roll)
Record Content: hospital , bed No. ,name, pregnancy weeks, patient No., paper speed, date,time , FHR data and wave, Contraction data and wave, Fetal move times and mark etc.
Ultrasound probe:
Nominal Frequency: 1.0 MHz
Work Frequency: 1.0 MHz±10 %
Negative peak sound pressure : p_<1 MPa
Output beam intensity : Iob<20 mW/cm2
The peak time space peak intensity: Ispta<100 mW/cm2
The average time space peak intensity: Isata<10 mW/cm2
FHR Rang: 50 BPM~240 BPM
Resolution: 1 BPM
Accuracy : ±2 BPM
TOCO
TOCO range: 0~100 %
Resolution: 1 %
Nonlinear error: <±10 %
RZ way: Manually
Fetal Marking
For the manual button (the operation of pregnant women), there will be a mark display in the bottom area of FHR wave display section.
FHR Alarm:
Alarm for high and low FHR, which exceeds appointed limit.